Efficiency scale for scattering luminescent particles linked to fundamental and measurable spectroscopic properties
Scientific Reports volume 13, Article number: 6254 (2023) Cite this article 514 Accesses Metrics details Comparing the performance of molecular and nanoscale luminophores and luminescent micro- and
Scientific Reports volume 13, Article number: 6254 (2023) Cite this article
514 Accesses
Metrics details
Comparing the performance of molecular and nanoscale luminophores and luminescent micro- and nanoparticles and estimating achievable signal amplitudes and limits of detection requires a standardizable intensity scale. This initiated the development of the relative MESF (number of molecules of equivalent soluble fluorochromes) and ERF (equivalent reference fluorophores) scales for flow cytometry and fluorescence microscopy. Both intensity scales rely on fluorescence intensity values assigned to fluorescent calibration beads by an intensity comparison to spectrally closely matching fluorophore solutions of known concentration using a spectrofluorometer. Alternatively, the luminophore or bead brightness (B) can be determined that equals the product of the absorption cross section (σa) at the excitation wavelength (σa(λex)) and the photoluminescence quantum yield (Φpl). Thereby, an absolute scale based on fundamental and measurable spectroscopic properties can be realized which is independent of particle size, material, and luminophore staining or labeling density and considers the sensitivity of the optical properties of luminophores to their environment. Aiming for establishing such a brightness scale for light-scattering dispersions of luminescent particles with sizes exceeding a few ten nanometers, we demonstrate how the brightness of quasi-monodisperse 25 nm, 100 nm, and 1 µm sized polystyrene particles (PSP), loaded with two different dyes in varying concentrations, can be obtained with a single custom-designed integrating sphere setup that enables the absolute determination of Φpl and transmittance and diffuse reflectance measurements. The resulting Φpl, σa(λex), imaginary parts of the refractive index, and calculated B values of these samples are given in dependence of the number of incorporated dye molecule per particle. Finally, a unitless luminescence efficiency (LE) is defined allowing for the direct comparison of luminescence efficiencies of particles with different sizes.
In the last decades, nanoparticles (NPs) and microparticles (MPs), stained or encoded with different types of molecular and nanocrystalline luminophores, have been increasingly used in the life and material sciences. Typical applications range from optical reporters for fluorescence assays and bioimaging and drug delivery systems over printable authentication tags and bead-based platforms for flow cytometry, fluorescence microscopy, and immune-separation to particle sensors and calibration tools for different fluorescence methods, particularly for flow cytometry1,2,3,4,5,6,7,8,9,10,11,12,13. Most fluorescence methods exploiting emissive NPs and MPs like fluorescence spectroscopy, microfluorometry, fluorescence microscopy, and flow cytometry measure only instrument-specific relative fluorescence intensities14. The reliable comparison of fluorescence measurements between different instruments and different laboratories requires an instrument calibration to determine and consider instrument-specific signal contributions such as the wavelength-dependent spectral responsivity of the instrument´s detection channel, that affect the measured emission spectra15,16. For the quantification of, e.g., analytes or the comparison of different fluorescent samples with different fluorescence techniques, commonly a relative calibration of the fluorescence intensity scale is performed using fluorophore solutions of known concentrations, luminescence properties, and particularly emission spectra closely matching that of the sample utilizing the same instrument settings as applied for the measurement of the sample17. This is straightforward for transparent luminescent samples, e.g., sensing applications or the quantification of luminophores with chromatographic separation techniques like high performance liquid chromatography (HPLC) with fluorescence detection, yet it is challenging for light-scattering systems. However, most dispersions of broadly used fluorescent NPs and MPs scatter the excitation light, depending on their size and the refractive index and environment of the particles. This can affect their fluorometric characterization and particularly measurements of their absorption features with common spectrophotometers and spectrofluorometers designed for the measurement of transparent samples.
The importance of quantifying scattering luminescent objects for example for flow cytometry used for blood, cell, and biomarker analysis in strongly regulated areas like the health sector and medical diagnostics recognized 30 years ago called for the establishment of a comparable and standardizable fluorescence intensity scale18. This initiated the development of the so-called relative MESF (number of molecules of equivalent soluble fluorochromes)19,20 and ERF (equivalent reference fluorophores)11 scales for measuring and quantifying the fluorescence intensity of fluorescent objectives in flow cytometry with the aid of luminescent calibration beads21. This concept is also utilized in fluorescence microscopy. The MESF and ERF scale rely on the comparison of the integral fluorescence intensities of a dispersion of dye-stained particles with a narrow size distribution of known concentration with a solution of a molecular fluorophore of known concentration with a closely matching emission spectrum. Thereby, the fluorescence intensity of the beads is expressed in terms of the intensity of this molecular fluorophore and the quantitative determination of the spectroscopic key parameters absorption cross section (σa(λ)) and photoluminescence or fluorescence quantum yield (Φpl) of the dye-stained beads is circumvented. These relative intensity calibration concepts have meanwhile led to the broad availability of a multitude of calibration beads with assigned MESF or ERF values adapted to the optical properties of typical fluorescent labels applied in flow cytometry. In addition, the reliability and accuracy of these concepts have been assessed for different types of core-stained or fluorophore labeled calibration beads by several interlaboratory comparisons of expert groups and different flow cytometers in the last decades. Thereby, limitations, caused, e.g., by the microenvironment- and dye-concentration dependent fluorescence efficiency of most fluorophores and different instrument designs including optical components used for flow cytometers have been examined22,23,24,25,26.
As an alternative to a relative fluorescence intensity scale, an absolute scale based on the fundamental spectroscopic properties σa(λex) and Φpl21,27, the ratio of the number of emitted photons per number of absorbed photons28, can be realized and used for quantification, e.g. in imaging studies29. The product of these two quantities is termed brightness (B) and controls the size of each fluorometrically detected signal from the sample side. This concept has been suggested for single molecules30, yet not for light-scattering dispersions of luminescent particles as light scattering renders the determination of σa(λex) and Φpl more difficult and requires special instrumentation. σa(λex) of particle dispersions can be derived from radiation transport theory, utilizing a spectrophotometer equipped with an integrating sphere for the measurement of the wavelength-dependent transmittance and diffuse reflectance (Rd). Φpl of light-scattering luminescent samples can be optically only accurately determined by integrating sphere spectroscopy27,31 and the increasing interest in such measurements initiated a renaissance of integrating sphere spectroscopy in the last decade32,33,34,35,36,37. For particles with sizes below 100 nm, where scattering is more or less isotropic, there are also very few reports on alternative relative spectroscopic methods, that are, however, more tedious and error prone. This includes a subtracting-based scattering correction of the measured absorbance at the excitation wavelength38, the addition of scatterers to the fluorescence quantum yield standard employed for the relative determination of Φpl, thereby matching the scattering features of sample and standard39, and the determination of the complex dielectric function of dye-loaded particles and consideration of the influence of Mie scattering40.
With the aim to establish a B scale for the characterization of the signal relevant properties of luminescent beads, we show in the following how B of light-scattering dispersions of luminescent particles can be obtained with a single custom-designed and traceably calibrated integrating sphere setup. This unique setup enables both the absolute determination of Φpl values as well as measurements of Rd, collimated transmittance (Tc), and diffuse transmission (Td) spectra of particle dispersions27. The determination of B values is demonstrated for dispersions of monodisperse 100 nm and 1 µm sized polystyrene particles (PSP), loaded with different concentrations of Nile Red and Itrybe molecules, chosen to vary in their solvatochromic behavior and spectral overlap between their absorption and emission bands (Stokes shift) and hence, concentration-dependent reabsorption41. Nile Red is a frequently employed polarity probe42,43 and polystyrene particles loaded with Itrybe and Nile Red were used by us before for dye loading studies41,42 and as tumor specific NIR-probe44 or the lifetime-based encoding of cells45. In this publication, we reevaluate previously determined B values of such dye-stained beads42 and provide the imaginary part of the refractive index. In addition, B and efficiency values from measured σa(λex) and Φpl data are given in dependence of the number of incorporated dye molecule per particle.
The experimental procedures used for the dye staining of the differently sized carboxyl-functionalized PSP and the absolute determination of Φpl values with our custom-designed integrating sphere setup enabling measurements of the fluorescence, Rd, Tc, and Td spectra of particle suspensions have been partly previously reported27,31,41,42,44,46.
Carboxyl-functionalized PSP with sizes of 25 nm, 100 nm, and 1 µm were purchased from Kisker Biotech GmbH. All particles were ultrasonically treated prior to use. Nile Red and Itrybe were obtained from Fluka GmbH and Otava Ltd, respectively. The solvents tetrahydrofuran (THF), dibutylether (BOB), and ethanol (EtOH) were of spectroscopic grade and purchased from Merck. All dyes and solvents were used as received.
For spectrally resolved measurements in the wavelength region from about 350 to 1000 nm, a custom designed and traceably calibrated integrating sphere setup was used enabling the free choice of the excitation wavelength27. This previously reported setup31,46 consisted of a 450 W xenon lamp, coupled to a single monochromator with 1200 L/mm gratings blazed at 330 nm, 500 nm, and 630 nm and an integrating sphere with a diameter of about 15 cm, coated with Spectraflect (Labsphere GmbH; sphere reflectivity of about 97% in the vis/NIR) as the sample compartment. The integrating sphere was coupled with a quartz fiber bundle to an imaging spectrograph (Shamrock 303i, Andor Technology PLC), equipped with 600 L/mm gratings, blazed at 500 nm and 750 nm that was attached to a Peltier cooled (183 K) thinned back side illuminated deep depletion charge coupled device (CCD array; 1024 × 256 pixel). The optical fiber was shielded from direct reflexes with several baffles to guarantee the detection of only diffuse radiation. To account for its fluctuations and for the measurements of the collimated transmittance two Peltier-cooled custom-designed silicon trap detectors47 were implemented into the integrating sphere setup.
To realize multiple measurement configurations or illumination conditions for the spectrally resolved measurements of the emission, reflection, and transmittance and an indirect sample illumination, the integrating sphere was equipped with several ports for the coupling of light into the sphere and sample mounting. For the absolute determination of Φpl, the sample was center-mounted inside the integrating sphere using a custom-designed Spectraflect-coated cuvette holder. The excitation light was focused with two off-axis parabolic mirrors into the middle (sample position) of the integrating sphere, thereby imaging the exit slit of the excitation monochromator onto the middle of the cuvette (see Supplementary Fig. S1)31. The radiant power reaching the sample was adjusted with an aperture, located in front of the integrating sphere. For the precise positioning of the cells inside the integrating sphere, a small HeNe laser was used in addition to the cuvette holder. The laser light reflected from the glass/air interface of the cuvette window was measured outside the integrating sphere.
For transmission and reflection measurements, a collimated beam is required. Therefore, the integrating sphere setup was slightly modified. The parabolic off-axis mirror 2 (see Supplementary Information (SI), Fig. S1) was exchanged by a plane mirror. Thereby, the spot size for reflection and transmission measurements could be adjusted with apertures behind the opened exit slit of the excitation monochromator. Custom designed sample holders for thin films and small volume cells were placed in front or behind the integrating sphere. The cells were designed to exactly fit the ports of the integrating sphere. Typical sample thickness for transmission and reflection measurements ranged from 200 µm to 1 mm with a diameter of 2.54 cm.
The absorption spectra of transparent solutions of the dyes Nile Red and the dyes released from the dye-stained PSP upon addition of THF were measured with Cary5000 UV–Vis-NIR spectrophotometer using 1 cm quartz cells from Hellma.
Dynamic light scattering measurements for particle size determination were performed with the Zetasizer from Malvern.
Commercial carboxylated PSP were stained with Nile Red and Itrybe via a previously reported swelling procedure27,41,42. In short, Nile Red and Itrybe were dissolved in THF in concentrations from 0.1 to 5 mmol/L. 100 µL of the dye-containing solution were added to 600 µL of an aqueous PSP suspension (3 mg/mL). 25 nm PSP were incubated for 30 min, whereas 100 nm and 1 µm PSP were incubated for 1 h. Then, 800 µL of water were added and the suspension was centrifuged (1 µm PSP (5,000 g, 10 min) and 100 nm PSP (15,000 g, 40 min) in a Eppendorf centrifuge 5415D, 25 nm PSP (75,000 g, 45 min) in a Beckman Coulter centrifuge Avanti J-20 XP. The stained PSP were washed twice and resuspended in bidistilled water.
The number of incorporated dye molecules per particle was photometrically determined after dissolving the particles by addition of THF48. In short, the stained PSPs were centrifuged, the supernatant removed and dissolved in THF. The dye concentration released from 3 mg PSP was calculated from absorbance measurements and the molar absorption coefficient, determined in THF in the presence of 0.1 w% dissolved polystyrene. The polystyrene mass concentration was determined by drying and weighing 1 mL of the aqueous suspension and the number of PSP per mg was determined by considering the particle volume and PS density (1050 kg/m3).
Our procedure of data acquisition for particle brightness and efficiency determination based on integrating sphere spectroscopy follows the schematic presentation illustrated in Fig. 1. For the determination of Φpl values, the absorbed (\({q}_{\mathrm{p}}^{\mathrm{abs}}\)) and emitted photon flux (\({q}_{p}^{pl}\)) are determined (see section on the “Determination of photoluminescence quantum yields”). In a next step reflection and transmission measurements were performed (see section on “Reflection and transmission measurements”) yielding Rd, Tt, Td and Tc. With these experimentally determined parameters, Φpl can be directly calculated (see section on the “Determination of photoluminescence quantum yields”). By solving the radiation transport theory, the scattering (µs), absorption coefficients (µa) and scattering anisotropy factor (g) can be calculated (see section on the calculation of µa, µs, and g). By implementing Mie theory, also the number of particles per unit volume (NP) the particle radius (rP) and the imaginary part of the refractive index (n2) (section on the “Determination of particle properties”) are determined. The resulting σa(λex) and Φpl values are finally used for the calculation of B and the luminescence efficiency (LE).
Flow chart of data acquisition and analysis: absorbed (\({q}_{\mathrm{p}}^{\mathrm{abs}}\)) and emitted photon flux (\({q}_{p}^{pl}\)). Diffuse reflectance (Rd), total (Tt), diffuse (Td), and collimated transmittance (Tc), scattering coefficients (µs), absorption coefficients (µa), scattering anisotropy factor (g), Fluorescence quantum yield (Φpl), number of particles per unit volume (NP), particle radius (rP), imaginary part of the refractive index (n2), absorption cross-section (σa), absorption efficiency (Qabs), and the particle luminescence efficiency (LE).
The optical response of an integrating sphere is dependent on its configuration (sample holder, baffle, port sizes etc.). For an ideal sphere, the magnification factor M(λ) is given by49:
\(\overline{\rho } (\lambda )\) represents the average wavelength-dependent reflectivity of the sphere surface which depends on the port areas Ai with their corresponding reflectivities \(\rho_{i} (\lambda )\) and the sphere’s surface area AS and reflectivity ρS(λ), respectively, (fi = Ai/AS). The incident radiant flux ϕe is diffusely reflected from a surface area with a reflectance ρ0(λ) (see Eq. 1, Fig. 2). The resulting the radiant flux ϕS reaching the sphere surface and generating the detector signal I is dependent on ϕe and M(λ):
Configurations of the integrating sphere setup, see also Supplementary Fig. S1, and the corresponding light fluxes (eq. S3) employed for (a) \({\Phi }_{pl}\) measurements, (b) Rd measurements, and (c, d) the measurement of Tt, Td, and Tc.
By further taking into account the detector surface AD and the spectral responsivity of the detection system s(λ), I can be written as:
Thus, each change of the integrating sphere configuration (see also Fig. 2) or surface, e.g., the exchange of a sample and a reference, changes the response of the integrating sphere setup and must be considered.
The photoluminescence quantum yield is defined as the quotient of the number of absorbed photons (Nabs) and the number of emitted photons (Nem) by a sample27,42,46,50, see Eq. (4).
\({\Phi }_{pl}\) of scattering samples like the suspensions of our dye-stained PSP can be only reliably determined by integrating sphere spectroscopy51. This involves the determination of the absorbed photon flux (\({q}_{p}^{abs}({\lambda }_{\text{ex}})\)) and the emitted photon flux (\({q}_{p}^{em}({\lambda }_{\text{em}})\)) of the sample (see Eq. (5) and Fig. 2a))31,46 with an integrating sphere setup.
The emitted photon flux follows from the blank and spectrally corrected emission spectrum of the sample (Ix(λem)) integrated over the emission band. The absorbed photon flux is calculated from the difference between the transmitted excitation light obtained with the blank (Ib(λex)) and the sample (Ix(λex)), within the wavelength region of the excitation bandwidth Δλ.
Reflection and transmission measurements were performed with the same integrating sphere setup as the quantum yield measurements. The sample was filled in cylindrical small-volume quartz cells with a thickness of 1 mm. For every recorded measured signal of a standard (index std) or sample (index S) or empty sphere (index empty) a reference measurement was done to account for changes of the magnification factor M(λ). For the calculation of the reflectance and transmittance the spectrally resolved signals I determined the integrating sphere were integrated in the spectral range of the excitation light \(E = \int\limits_{{\lambda_{ex} - \Delta \lambda }}^{{\lambda_{ex} + \Delta \lambda }} {I(\lambda_{{{\text{ex}}}} )} d\lambda_{{{\text{ex}}}}\). The spectrally resolved detection has the advantage that also strongly fluorescent samples can be investigated. Integrating spheres equipped only with photomultiplier tubes or photodiodes cannot distinguish between excitation/incident light and the red shifted luminescence and are therefore not suited for reflectance and transmission of luminescent materials.
For measurements of Rd the sample was mounted with special sample holders on the back of the integrating sphere (R-Port Fig. 2b)), Rd was then calculated with respect to NIST certified diffuse reflectance standards according to:
RStd(λ) equals the certified Rd value of the reflectance standard, Ee(λ) and ERef(λ) stand for the detector signal with direct and indirect sample illumination, respectively. ED indicates a dark measurement to remove a signal offset. The subscripts S and Std stand for measurements of the sample and the standard mounted at the reflectance port, respectively. The first reflection from the sample’s glass surface (RFresnel) was included in the measurements.
For each transmission measurement, the sample was mounted at the entrance port of the integrating sphere. The transmitted radiation (Ttotal) can be separated into two parts, the directly or collimated (Tc) and the diffusely (Td) transmitted radiation:
Photons, that are collimatedly transmitted, pass the sample without interaction and have thus the same propagation direction as the incident photons, while diffusely transmitted photons are scattered at least once. The total transmittance was measured with the integrating sphere configuration shown in in Fig. 2c) and calculated with Eq. (8). With the same configuration but an open port on the back of the integrating sphere (R-port), the diffuse transmittance can be determined, see Fig. 2d) and Eq. (8).
In principle Tc can be calculated from the total and diffuse transmitted photon flux (Eq. 7). But the open R-port for measurements of Rd causes losses of diffusely scattered photons leading to an incorrect calculation of Tc. These errors correlate with the size of the R-port and the diameter of the integrating sphere. Therefore, a trap detector was used to measure Tc. Our trap detector consists of three silicon photodiodes arranged in a 60° geometry to trap the incident light. This trap detector with an aperture of 0.5 mm was positioned in a distance of 1.5 m behind the sample to reduce the solid angle for scattered and emitted photons contributing to measurements of Tc. Tc was then calculated from the signals of the trap detector ITrap:
In strongly scattering media the propagation of light can be described by the radiation transport theory:
The light distribution inside a sample is defined by L(r,s), which stands for the vectored radiance at the point r in the propagation direction s (illustrated in the SI in Fig. S2). To facilitate reading we neglect vector notations here. L(r,s) depends on the number of absorbing and scattering particles in the sample described by µa and µs, the absorption and scattering coefficients. p(s, \(\tilde{s}\) λ) is the phase-function for scattering processes and \(d\Omega\) is the solid angle. S(r,s) is a source term for the isotropically emitted fluorescence in the sample at the point r and depends on the density of the excited fluorophores and L(r,s) at the fluorophore position. The propagation of light is illustrated in the SI in Fig. S2. With the knowledge of the three parameters Tt, Tc (or Td), and Rd, the radiation transport theory can be solved with approaches like the Kubelka–Munk theory, Monte Carlo methods, and the inverse adding doubling (iAD) method to calculate the sample-specific parameters µa, µs, and g52,53,54,55,56. g is the mean cosine of the scattering phase function, which can be calculated from Mie theory. Typically, the phase function is reduced to a more simplified model like the Henyey-Greenstein phase function (HG) or the Gegenbauer Kernel phase function57,58. To solve the radiation transport theory and determine the wavelength-dependent parameters µa(λ), µs(λ), and g(λ), we used the freely accessible iAD method by Prahl et al.52. Here the HG phase function is already implemented, which best fits the scattering phase function of polystyrene particles. For luminescent samples, the source term S(r,s) which depends on σa(λex) and Φpl of the luminophore has to be eliminated. Also, the first reflection of the incident radiation has to be considered.
With our approach, we detect the spectrally resolved transmitted and reflected photon fluxes (see section on “Reflection and transmission measurements”). Therefore, we could separate emitted photons from the incident/transmitted light and calculate the undisturbed reflection and transmittance. This allows the solution of Eq. (9) without taking into account the source term for the fluorescence (S(r,s)).
The scattering and absorption coefficients determined from reflection and transmission measurements and the solution of the radiation transport theory are effective sample parameters and do not directly reveal information about single particle properties. If the number of particles per unit volume (Np) is known the absorption and scattering cross sections (\({\upsigma }_{\mathrm{a},\mathrm{s}}(\uplambda ))\) can be directly calculated from the absorption coefficient \({\mu }_{a}(\lambda )\) calculated via the iAD method.
For polydisperse samples, this cross section is the average over the size distribution. Further, if also the particle radius rp is known the scattering and absorbance efficiencies (Qa,s \((\lambda )\)) can be determined. Qa,s \((\lambda )\) is defined in Eq. (12) as the ratio of the corresponding cross section and the physical cross section of a particle.
The determination of Np can be rather challenging. With the knowledge of the rp and its distribution a defined sample amount can be dried, and the number of particles can be calculated from the mass resulting and density of the particle material. For this method, a sufficiently large sample amount is required. Unfortunately, the dried particles are often not easily redispersed. Also, a flow cytometer or calibrated nanoparticle tracking analysis (NTA) can be used to determine the particle concentration but for these approaches the samples often need to be strongly diluted. rp can also be determined, e.g., by scattering methods like dynamic or static light scattering (DLS, SLS) which analyze the scattered light intensity fluctuation or spatial intensity distribution. Also, e.g., small angle X-ray scattering (SAXS) or NTA59,60 or image-based techniques like transmission and scanning electron microscopy (TEM, SEM) can be used. The latter image-based methods, that measure individual particles, can be time consuming as a statistically relevant number of particles have to be measured to accurately determine the size distribution.
A straightforward approach not needing any other instrumentation is the theoretical description of optical particle properties via the rigorous scattering theory (Mie theory), i.e., the solution of the wave equation for spherical boundary conditions. σs(λ), σa(λ), p(λ), and g(λ) can be theoretically predicted and adapted to the solution of the radiation transport theory.
The cross sections (σa,s) are calculated from the fundamental parameters an and bn:
with y = πmd/λmed and x = πd/λmed and the Ricatti-Bessel functions ψn and ζn These fundamental parameters depend on the complex relative refractive index m between the particle (np) and the medium (nmed), the particle radius (rP), and the wavelength in the outer medium λmed = λ/nmed. We used the codes from Mätzler61 and modified them to calculate the wavelength-dependent scattering and absorption coefficients. Finally, we generated a least square fitting algorithm based on the Mie- and radiation transport theory. Input parameters for this routine are \({\mu }_{a}(\lambda )\), \({\mu }_{s}(\lambda )\), \({g}_{s}\left(\lambda \right),\) and the material properties, e.g., the refractive indices of the solvent and the particle62. As free parameters for the fitting procedure, not only Np and rp but also the width of the size distribution function was used to consider the polydispersity of the bead dispersion. The fitting procedure finally provides rp, Np, and the imaginary part of the refractive index (n2) of the particles. Alternatively, the real part of the refractive index can be determined if the particles size is known63.
To precisely determine rp via fitting a characteristic wavelength dependence of \({\mu }_{s}(\lambda )\) is necessary, exhibiting oscillatory behavior (Mie resonances). This depends on the solvent, particle material, and size as well as the investigated wavelength region. E.g., for polystyrene particles with a diameter in the order of 1 µm and larger, dispersed in water, rp and Np can be determined. For particles, which do not exhibit a characteristic wavelength dependence of µs(λ), the knowledge of the particle size is necessary to determine the number of particles per unit volume. This is similar to previously presented method(s) based on Tc.64
The real and imaginary parts of the complex refractive index \({n\left(\lambda \right)={n}_{1}\left(\lambda \right)+{\text{i}}\hspace{0.17em}{n}_{2}\left(\lambda \right)}\) of a material are linked by so-called Kramers–Kronig (KK) relations. For example, \({n}_{1}\left(\lambda \right)\) is related to \({n}_{2}\left(\lambda \right)\) by
Here, \(P\int\) denotes the Cauchy principal value integra and \(\lambda\) the wavelength in vacuo. Note that the integral is taken over all wavelengths (or frequencies) from zero to infinity. The real part of the refractive index is influenced by the absorption spectrum at all other wavelengths.
The complex refractive index of a PSP containing a dye at an intra-particle molar concentration \({c}^{\text{dye}}\) is given by
The increment of the imaginary part is related to the molar extinction coefficient of the dyes Nile Red and Itrybe by
The unit for the refractive index increments \(\widetilde{\alpha }\left(\lambda \right), \widetilde{\gamma }\left(\lambda \right)\) is that of an inverse molar concentration—L/mol. Assuming, that the matrix (i.e., polystyrene) is quasi-non-absorbing in the wavelength range considered here, we set \({n}_{2}^{\text{matrix}}\left(\lambda \right)=0\). Under the assumption that outside of a wavelength range \(\left[{\lambda }_{a},{\lambda }_{b}\right]\) (e.g., the visible range) the absorption of the matrix material polystyrene and the dye is similar, the real part of the refractive index increment can be calculated according to
If the spectra outside the range \(\left[{\lambda }_{a},{\lambda }_{b}\right]\) do not match, additional constant or normal-dispersion terms with positive or negative signs may occur in \(\widetilde{\alpha }\left(\lambda \right)\).
For numerical evaluation, we used measured spectra of the molar extinction coefficient \(\varepsilon \left(\lambda \right)\) to obtain \(\widetilde{\gamma }\left(\lambda \right)\). The integral in Eq. (18) was then evaluated in a range \(\left[{\lambda }_{a},{\lambda }_{b}\right]\) covering the main peak of the spectrum. For NR this was 300–700 nm. The spectra were interpolated to a step size of 0.5 nm and the (KK) integral was numerically evaluated65. The wavelength grid spacing of the resulting \(\widetilde{\alpha }\left(\lambda \right)\) data was increased (downsampling) to the desired value (e.g., 5 nm) for Mie scattering calculations and comparison with measured spectra.
To obtain the complex refractive index for Mie calculations, we determined the average dye loading concentration per particle by photometric measurements of the absorption spectra of the dye molecules released upon particle dissolution with THF (see section on “Determination of particle properties”) and Eq. (18).
To assess our measurement procedures and algorithms, different aqueous dispersions of monodisperse, quasi non-absorbing polystyrene microspheres with varying particle diameters and defined concentrations were used. Examples are shown in Fig. 3 and in the SI in Figs. S3 (d ≈ 1 µm) and S4 (d ≈ 2.5 µm). Here, we determined Tt, Tc, and Rd of a dispersion of PSP with a diameter of ca. 1250 nm. The sum of Tt and Rd equals 0.95 due to small scattering losses which depend on the sample and the integrating sphere geometry (see Fig. 3a)). These losses can differ for samples with different scattering properties and sample thicknesses but are considered in the iAD routine by Prahl et al.52. If not completely compensated these losses result in an offset in the absorption coefficient. Consequently, the radiation transport theory with Tt, Tc, and Rd as input parameters was solved for all samples to determine the wavelength-dependent scattering coefficient (µs(λ), Fig. 3b)) and the wavelength-dependent anisotropy factor (g(λ), Fig. 3c)). These results were then fitted with Mie theory to determine Np and rp, the latter was additionally validated with DLS measurements (Fig. 3d yielding rp,DLS = 1291 nm. The fitting procedure yields a good agreement between the solution of radiation transport and Mie theory and the resulting particle radius and particle concentrations confirm the suitability of our approach.
Dispersion of unstained polystyrene particles with about 1.25 µm diameter. (a) Diffuse reflectance (Rd, triangles), total (Tt, triangles) and collimated transmittance (Tc, solid circles) and sum of Rd and Tt (solid squares). (b) Scattering coefficient (µs) calculated from the radiation transport theory (solid squares) and Mie theory (red line). (c) Anisotropy factor g calculated from the radiation transport theory (solid squares) and Mie theory (red line). (d) Size distribution function determined with DLS (solid circles, black line) and Mie theory (red line).
To evaluate our method with absorbing and luminescent particles, quasi-monodisperse model systems were prepared and characterized as described in the “Methods” section. We focussed on particles with sizes of 25 nm, 100 nm, and 1 µm, the latter exhibiting strong anisotropic scattering behaviors (g > 0). The normalized absorbance and emission spectra of aqueous dispersions of these differently sized PSP loaded with Nile Red and Itrybe are displayed in the SI in Fig. S5. Due to the dye staining of the particles via a previously optimized swelling procedure assessed, e.g., microscopy, the dye molecules can be assumed to be homogeneously distributed within the particles, and the spherical shape of the particles is preserved in the process.12,41,42,44 This allows for a data analysis based on Mie Theory, like with the unstained particles discussed above. The absorbance and emission spectra of Itrybe-loaded PSP are broadened compared to the parent molecule in ethanol, yet the respective absorption and emission maxima match. In the case of solvatochromic Nile Red, the absorbance and emission bands of Nile Red-stained PSP are red shifted with decreasing PSP size, pointing to an increasingly polar microenvironment faced by the dye molecules with reduced PSP size and hence increased surface-to-volume ratio. The corresponding \({\Phi }_{\mathrm{pl}}\) of aqueous dispersions of Nile Red- and Itrybe-loaded PSPs in dependence on PSP size and loading concentration, i.e., the average dye-dye distance are shown in Fig. 4. This figure reveals opposite trends for the particle size- and dye loading-dependent \({\Phi }_{\mathrm{pl}}\) of both dyes. As shown in the left panel of Fig. 4, the \({\Phi }_{\mathrm{pl}}\) values of Nile Red-stained PSP decreased with decreasing PSP size and increased surface-to-volume ratio. In contrast, for PSP containing Itrybe molecules, \({\Phi }_{\mathrm{pl}}\) decreased with increasing particle size (right panel of Fig. 4. For both dyes, an increase in dye loading concentration resulted in a diminution of \({\Phi }_{\mathrm{pl}}\) (see also SI, Fig. S7). We attribute these trends to (1) the influence of the polar particle environment particularly in the case of the charge transfer dye Nile Red, the fluorescence of which is known to be quenched by hydrogen bonding interactions and polarity as follows also from the solvatochromic emission behavior of Nile Red (see SI, Fig. S5), (2) dye-dye interactions, and (3) energy transfer processes between dye molecules in the PSP. The latter two factors are supported by the dependence of \({\Phi }_{\mathrm{pl}}\) on dye loading concentration (see Fig. 4 and SI, Fig. S7)66,67,68,69,70. µa(λ) and µs(λ) of the dispersed 1 µm and 100 nm dye loaded PSPs determined by radiation transport and Mie Theory are shown in Fig. 5. For the 25 nm sized particles the scattering contributions were too small to be used for quantification and represent the physical size limit for our study and method development. For the fit of µa(λ) and µs(λ), we considered the contribution of the dye molecules to the dielectric function of the particle matrix by increasing the imaginary part of the refractive index. In a first step, n2 was used as a free variable and it was assumed that the particle matrix is homogeneously loaded with dye molecules. The resulting σa(λ) values are shown in Fig. 6. The resulting Np and rp values were also used for the determination of σa(λ) from µa(λ) calculated from the radiation transport theory. For the particle sizes and dye concentrations used here, the direct determination of σa(λ) from Mie calculations and calculations using radiation transport theory are in good agreement as displayed in Fig. 5.
Photoluminescence quantum yields of 1 µm (circles), 100 nm (squares), and 25 nm (triangles) PSP loaded with Nile Red41 (left) and Itrybe (right) in dependence on the mean distance between the dye molecules. The lines are only a guide to the eye. The dashed lines indicate the max. \({\Phi }_{\mathrm{pl}}\) in solution of the free dyes, i.e., Itrybe dissolved in ethanol and Nile Red in BOB.
Example of calculated scattering coefficients (µs, top, open circles) and absorption coefficients (µa, bottom, filled circles) from reflection and transmittance measurements of Nile Red-loaded 1 µm (left) and 100 nm (right) PSP. Fits of Mie theory are indicated by red lines.
Left: Absorption cross sections of 100 nm (top) and 1 µm (bottom) PSP loaded with Nile Red (circles) and Itrybe (squares) in dependence of the incorporated number of dye molecules per particle. Right: Absorption efficiency (Qabs) of the dye-loaded PSP in dependence of the imaginary part for the refractive index n2 for 1 µm PSP (solid symbols) and 100 nm PSP (open symbols) loaded with Nile Red (circles) and Itrybe (squares).
So far, we treated the real part of the refractive index and the imaginary part as independent quantities. In the Mie scattering calculations, we set the imaginary part of the dye-stained PSP according to an absorption line of the dye Nile Red or Itrybe but assumed that the real part equals that of unstained PSP. When Eqs. (16)–(18) are applied to the stained particles, a dye-concentration-dependent contribution to \({n}_{1}\left(\uplambda \right)\) that features an anomalous dispersion (i.e., locally, with the refractive index decreasing with wavelength) which was neglected so far and “Materials and methods” section for more details. We repeated the Mie scattering calculations including also the term due to the KK relations for the complex refractive index of the particles. Results of this physically more complete model are shown in the SI in Fig. S6 for 1 µm-sized PSP stained with Nile Red. Generally, \({\mu }_{a}\left(\uplambda \right)\) remains practically unaffected by the KK contribution to \({n}_{1}\left(\uplambda \right)\), whereas some spectral features of \({\mu }_{s}\left(\uplambda \right)\) changed noticeably. Since \({\mu }_{s}\left(\uplambda \right)\) is utilized to determine the particle size and particle number concentration, an error is introduced into this approach by omitting the KK term. For the 1 µm particles, we estimated the corresponding uncertainty to be about 5% for the mean particle diameter, which is accordingly underestimated, and to about 10% for the particle concentration, that is hence overestimated, depending on the exact workflow of the data analysis. For smaller particles, the effect of the KK relations on \({\mu }_{\mathrm{s}}\left(\uplambda \right)\) decreases and can be neglected for diameters ≤ 100 nm.
As shown in the left panel of Fig. 6, σa(λ) linearly increased up to 7 × 104 and 1.8 × 107 incorporated Nile Red or Itrybe molecules for 100 nm and 1 µm PSP. The impact of dye loading on the effective particle properties, i.e., Qabs and n2 is displayed in the right panel of Fig. 6. For 100 nm-sized PSP, Qabs is considerably smaller compared to 1 µm PSP. An extrapolation shows that also for higher dye loading concentrations, i.e., n2, the efficiency increases linearly. For 1 µm particles the relation between Qabs and n2 is no longer linear for dye concentrations exceeding the concentrations used in this study.
The product of \({\Phi }_{\mathrm{pl}}\) and σa(λ) can be used to calculate the brightness (B) of a particle as done before for the B value of a dye molecule as shown in Fig. 7. For molecular luminophores like dye molecules, B is typically given as the product of \({\Phi }_{\mathrm{pl}}\) and the molar decadic absorption coefficient (ε(λ)) which is related to the oscillator strength of the emitting dipole. In contrast to dye molecules, σa(λ) of particles scale with rp, n2, and \({\Phi }_{\mathrm{pl}}\). The latter is related to the number of dye molecules incorporated into the particle (see Figs. 4 and 6), dye-dye interactions, and dye-specific properties like the oscillator strength and \({\Phi }_{\mathrm{pl}}\) in the respective environment. Earlier, we calculated the particle brightness from the product of the number of molecules per particle, the corresponding ε of the dye determined in a model solvent such as BOB, and the measured \({\Phi }_{\mathrm{pl}}\) of the particle dispersion (\({{N}_{\mathrm{Dye}}\cdot\upvarepsilon ({\lambda }_{ex})\cdot \Phi }_{\mathrm{pl}}\))27,71, see Fig. 7 (left panel). This approximation, that is valid for small particles and low dye loading concentrations, has several drawbacks. As shown in the SI in Fig. S5, (1) ε can depend on dye environment and can only be measured in a solvent which mimics the dye environment inside the particle. Mimicking implies here ideally a comparable polarity and refractive index. (2) For the determination of NDye, the particles need to be dissolved and (3) for high dye loading concentrations, the σa(λ) must not necessarily be linearly related with the amount of incorporated dye molecules. An advantage of this method is that B values of very small particles like. 25 nm-sized polymer beads can be determined (Fig. 7, left panel).
Left: Brightness with a unit of L/(mol*cm) calculated as the product of the number of dye molecules inside a particle (NDye), the quantum yield and the molar decadic absorption coefficient of the respective dye. Right: Determined brightness values with a unit of (1/cm2) in dependence of the dye amount per nm3. 1 µm (full symbols) and 100 nm (open symbols) and 25 nm (open symbols with centered dot) PSP loaded with Nile Red (circles) and Itrybe (squares). Both graphs cover 7 orders of magnitude.
The definition of particle brightness by Eq. (19) clearly represents a more general approach as all parameters are experimentally accessible with integrating sphere spectroscopy (see Fig. 7, right panel). A direct comparison of the two approaches utilized for the determination of B values of luminescent particles in units of (L/(mol*cm) and (1/cm2) is shown in Fig. 7 (and SI, Fig. S8, for one swelling batch).
As can be seen in Figs. 4, 6, and 7 and in Supplementary Fig. S8, apparently \({\Phi }_{\mathrm{pl}}\) is not the quantity, the value of which dominates the measured signal amplitude recorded for a luminescent particle, but the σa(λ). For example, the latter quantity is a factor of 100 to 1000 larger for 1 µm PSP compared to 100 nm PSP. 1 µm sized particles loaded with Itrybe have a \({\Phi }_{\mathrm{pl}}\) of less than 1% but show a B value higher than that of 100 nm sized PSP loaded with Nile Red that exhibit a \({\Phi }_{\mathrm{pl}}\) of 76%. Figure 7 indicates optimum dye loading concentrations for high B values. Apparently, for both dyes, the highest B values were obtained for a dye loading concentration range of 0.83 × 10–8 to 2.1 × 10–8 mol per mg PSP.
Finally, to cancel out the influence of the physical size of the luminescent particles and to introduce a size-independent luminescence efficiency (LE) for luminescent particles, we calculated the luminescence efficiency (LE) of dispersions of luminescent particles as the product of the photoluminescence quantum yield \({\Phi }_{\mathrm{pl}}\) and the absorption efficiency (Qabs) of a particle:
LE values as defined here by us is a unitless number between 0 and 1 and represents the ratio of the photons incident on the particle cross section and the photons emitted by the particle (see Fig. 8).
Luminescence efficiency LE of 1 µm (full symbols) and 100 nm (open symbols) PSP loaded with Nile Red (circles) and Itrybe (squares).
In terms of LE (Fig. 8), 100 nm Nile Red-stained PSP clearly exceed 1 µm Itrybe-loaded PSP. In addition, the particle LE scaled over the incorporated dye amount per 3 mg PSP is shown in the SI in Fig. S9. For applications where particle ensembles are utilized and not single particles like, e.g., analyte-responsive nanosensors, carrier beads for bead-based assays or light or energy conversion layers, particle LE reflecting the photon shifting efficiency may be the more important parameter for the characterization of luminescent particles and the comparison of their performance.
In summary, we presented a brightness (B) scale for the performance evaluation and comparison of light-scattering dispersions of luminescent particles that expresses the signal-relevant optical properties of the particles in terms of fundamental spectroscopic quantities. This brightness scale is based upon measurements of the absorption cross section and the photoluminescence quantum yield (Φpl) with a single integrating sphere setup custom-designed to enable the absolute determination of Φpl and transmittance and diffuse reflectance measurements.
This concept of classifying particle B values, was exemplarily shown for aqueous dispersions of quasi-monodisperse 25 nm-, 100 nm-, and 1 µm-sized spherical polystyrene particles, homogeneously core stained with two dyes in varying concentrations. These fluorophores were chosen to differ in their solvatochromic behavior and spectral overlap between their absorption and emission bands and hence reabsorption. Subsequently, Φpl of these materials and the optical properties, i.e., the absorption and scattering coefficients µa and µs were determined from solutions of the radiation transport theory based on reflection and transmission measurements of the particle dispersions with our integrating sphere setup. This procedure was validated with unstained materials. For our model compounds, we further calculated σa(λ), n2, and Qabs(λ) in dependence of the number of incorporated dye molecules taking into account Mie theory. Finally, we defined a unitless luminescence efficiency (LE) as the product of the absorption efficiency and Φpl which effectively represents the fraction of absorbed and reemitted photons of a particle and determined these values for dye-stained particles.
Overall, the described procedure allows for the determination of scattering and absorption properties of light scattering particle-containing media, the determination of number concentrations, and material constants as well as the identification of the particles with the best luminescence performance for technical and biological applications with just one integrating sphere setup. The lower limit for particle size is around 50 nm, depending on the particle and solvent refractive index. This concept, that can be also realized with a photometer equipped with an integrating sphere and a stand-alone integrating sphere setup for the absolute measurement of Φpl values, has the potential to overcome relative intensity comparisons and can provide a more general intensity scale for photoluminescent light scattering particles. In the future, we will further explore the implementation of the Kramers Kronig relations into the Mie fitting algorithm regarding an optimized parameter weight.
All data generated or analyzed during this study are included in this published article (and its Supplementary Information (SI) files) or are available upon request from the corresponding authors.
Mosshammer, M., Brodersen, K. E., Kuhl, M. & Koren, K. Nanoparticle- and microparticle-based luminescence imaging of chemical species and temperature in aquatic systems: A review. Microchim. Acta 186, 2. https://doi.org/10.1007/s00604-018-3202-y (2019).
Article CAS Google Scholar
Rodiger, S. et al. Nucleic acid detection based on the use of microbeads: A review. Microchim. Acta 181, 1151–1168. https://doi.org/10.1007/s00604-014-1243-4 (2014).
Article CAS Google Scholar
Carrillo-Carrion, C., Escudero, A. & Parak, W. J. Optical sensing by integration of analyte-sensitive fluorophore to particles. Trac-Trends Anal. Chem. 84, 84–96. https://doi.org/10.1016/j.trac.2016.05.001 (2016).
Article CAS Google Scholar
Clark, H. A., Kopelman, R., Tjalkens, R. & Philbert, M. A. Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors. Anal. Chem. 71, 4837–4843. https://doi.org/10.1021/ac990630n (1999).
Article CAS PubMed Google Scholar
Kromer, C. et al. Monitoring and imaging pH in biofilms utilizing a fluorescent polymeric nanosensor. Sci. Rep. 12, 1. https://doi.org/10.1038/s41598-022-13518-1 (2022).
Article ADS CAS Google Scholar
Srivastava, P. et al. multicolor polystyrene nanosensors for the monitoring of acidic, neutral, and basic pH values and cellular uptake studies. Anal. Chem. 94, 9656–9664. https://doi.org/10.1021/acs.analchem.2c00944 (2022).
Article CAS PubMed Google Scholar
Shao, S. et al. Preparation of fluorescence-encoded microbeads with large encoding capacities and application of suspension array technology. New J. Chem. https://doi.org/10.1039/D2NJ00628F (2022).
Article Google Scholar
Zhang, J., Shikha, S., Mei, Q., Liu, J. & Zhang, Y. Fluorescent microbeads for point-of-care testing: A review. Microchim. Acta 186, 361. https://doi.org/10.1007/s00604-019-3449-y (2019).
Article CAS Google Scholar
Sowa, M. et al. Next-generation autoantibody testing by combination of screening and confirmation-the CytoBeadA (R) technology. Clin. Rev. Allergy Immunol. 53, 87–104. https://doi.org/10.1007/s12016-016-8574-3 (2017).
Article CAS PubMed Google Scholar
Perfetto, S. P., Ambrozak, D., Nguyen, R., Chattopadhyay, P. & Roederer, M. Quality assurance for polychromatic flow cytometry. Nat. Protoc. 1, 1522–1530 (2006).
Article CAS PubMed Google Scholar
Wang, L. L. & Gaigalas, A. K. Development of Multicolor Flow Cytometry Calibration Standards: Assignment of equivalent reference fluorophores (ERF) unit. J. Res. Nat. Inst. Stand. Technol. 116, 671–683. https://doi.org/10.6028/jres.116.012 (2011).
Article CAS Google Scholar
Hoffmann, K., Nirmalananthan-Budau, N. & Resch-Genger, U. Fluorescence calibration standards made from broadband emitters encapsulated in polymer beads for fluorescence microscopy and flow cytometry. Anal. Bioanal. Chem. 412, 6499–6507. https://doi.org/10.1007/s00216-020-02664-y (2020).
Article CAS PubMed PubMed Central Google Scholar
Wu, Y. et al. The development of quantum dot calibration beads and quantitative multicolor bioassays in flow cytometry and microscopy. Anal. Biochem. 364, 180–192. https://doi.org/10.1016/j.ab.2007.02.006 (2007).
Article CAS PubMed PubMed Central Google Scholar
Resch-Genger, U. et al. How to improve quality assurance in fluorometry: Fluorescence-inherent sources of error and suited fluorescence standards. J. Fluoresc. 15, 337–362 (2005).
Article CAS PubMed Google Scholar
Resch-Genger, U., Hoffmann, K. & Pfeifer, D. In Reviews in Fluorescence Vol. 4 Reviews in Fluorescence (ed Geddes, C. D.) Ch. 1, 1–32 (Springer Science Businesss Media, Inc., 2009).
Resch-Genger, U. & DeRose, P. C. Characterization of photoluminescence measuring systems (IUPAC Technical Report). Pure Appl. Chem. 84, 1815–1835. https://doi.org/10.1351/PAC-REP-10-07-07 (2012).
Article CAS Google Scholar
Resch-Genger, U. & de-Rose, P. Fluorescence standards: Classification, terminology, and recommendations on their selection, use, and production (IUPAC Technical Report). Pure Appl. Chem. 82, 2315–2335 (2010).
Article CAS Google Scholar
Schwartz, A., Repollet, E. F., Vogt, R. & Gratama, J. W. Standardizing flow cytometry: Construction of a standardized fluorescence calibration plot using matching spectral calibrators. Cytometry 26, 22–31. https://doi.org/10.1002/(sici)1097-0320(19960315)26:1%3c22::aid-cyto4%3e3.0.co;2-i (1996).
3.0.co;2-i" data-track-action="article reference" href="https://doi.org/10.1002%2F%28sici%291097-0320%2819960315%2926%3A1%3C22%3A%3Aaid-cyto4%3E3.0.co%3B2-i" aria-label="Article reference 18" data-doi="10.1002/(sici)1097-0320(19960315)26:13.0.co;2-i">Article CAS PubMed Google Scholar
Schwartz, A. et al. Formalization of the MESF unit of fluorescence intensity. Cytometry Part B-Clinical Cytometry 57B, 1–6 (2004).
Article Google Scholar
Marti, G. E. et al. Fluorescence calibration and quantitative measurements of fluorescence intensity, approved guideline. IN NCCLS, I/LA24-A 24 (2004).
Wong, K. L., Bunzli, J. C. G. & Tanner, P. A. Quantum yield and brightness. J. Luminesc. 224, 117256. https://doi.org/10.1016/j.jlumin.2020.117256 (2020).
Article ADS CAS Google Scholar
Waxdal, M. J., Monical, M. C. & Palini, A. G. Inter-laboratory relative fluorescence intensity measurements using FlowCal 575 calibration beads: A baseline study. Cytometry 33, 213–218 (1998).
3.0.CO;2-X" data-track-action="article reference" href="https://doi.org/10.1002%2F%28SICI%291097-0320%2819981001%2933%3A2%3C213%3A%3AAID-CYTO16%3E3.0.CO%3B2-X" aria-label="Article reference 22" data-doi="10.1002/(SICI)1097-0320(19981001)33:23.0.CO;2-X">Article CAS PubMed Google Scholar
Lenkei, R. et al. Performance of calibration standards for antigen quantitation with flow cytometry. Cytometry 33, 188–196. https://doi.org/10.1002/(sici)1097-0320(19981001)33:2%3c188::aid-cyto13%3e3.0.co;2-q (1998).
3.0.co;2-q" data-track-action="article reference" href="https://doi.org/10.1002%2F%28sici%291097-0320%2819981001%2933%3A2%3C188%3A%3Aaid-cyto13%3E3.0.co%3B2-q" aria-label="Article reference 23" data-doi="10.1002/(sici)1097-0320(19981001)33:23.0.co;2-q">Article CAS PubMed Google Scholar
Wang, L. et al. Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti-CD4 FITC antibody. Cytometry A 87A, 254–261. https://doi.org/10.1002/cyto.a.22634 (2015).
Article CAS Google Scholar
Saraiva, L. et al. Comparison of volumetric and bead-based counting of CD34 cells by single-platform flow cytometry. Cytometry Part B-Clin. Cytometry 96, 508–513. https://doi.org/10.1002/cyto.b.21773 (2019).
Article CAS PubMed Google Scholar
Hoffman, R. A., Wang, L. L., Bigos, M. & Nolan, J. P. NIST/ISAC standardization study: Variability in assignment of intensity values to fluorescence standard beads and in cross calibration of standard beads to hard dyed beads. Cytometry A 81A, 785–796. https://doi.org/10.1002/cyto.a.22086 (2012).
Article Google Scholar
Huber, A., Behnke, T., Würth, C., Jaeger, C. & Resch-Genger, U. Spectroscopic characterization of coumarin-stained beads: Quantification of the number of fluorophores per particle with solid-state 19F-NMR and measurement of absolute fluorescence quantum yields. Anal. Chem. 84, 3654–3661. https://doi.org/10.1021/ac3000682 (2012).
Article CAS PubMed Google Scholar
Lakowicz, J. R. Principles of fluorescence spectroscopy 3rd edn. (Springer Science+Business Media LLC, 2006).
Book Google Scholar
Williams, N. D. et al. DNA-origami-based fluorescence brightness standards for convenient and fast protein counting in live cells. Nano Lett. 20, 8890–8896. https://doi.org/10.1021/acs.nanolett.0c03925 (2020).
Article ADS CAS PubMed PubMed Central Google Scholar
Yuxi, T., Johannes, H., Michal, W., Dibakar, S. & Ivan, G. S. Quantitative measurement of fluorescence brightness of single molecules. Methods Appl. Fluoresc. 2, 035003 (2014).
Article Google Scholar
Würth, C. & Resch-Genger, U. Determination of photoluminescence quantum yields of scattering media with an integrating sphere: Direct and indirect illumination. Appl. Spectrosc. 69, 749–759. https://doi.org/10.1366/14-07679 (2015).
Article ADS CAS PubMed Google Scholar
Valenta, J. Determination of absolute quantum yields of luminescing nanomaterials over a broad spectral range: From the integrating sphere theory to the correct methodology. Nanosci. Methods 3, 11–27. https://doi.org/10.1080/21642311.2014.884288 (2014).
Article CAS Google Scholar
Kobayashi, A., Suzuki, K., Yoshihara, T. & Tobita, S. Absolute measurements of photoluminescence quantum yields of 1-halonaphthalenes in 77K rigid solution using an integrating sphere instrument. Chem. Lett. 39, 282–283. https://doi.org/10.1246/cl.2010.282 (2010).
Article CAS Google Scholar
Hasebe, N. et al. Absolute phosphorescence quantum yields of singlet molecular oxygen in solution determined using an integrating sphere instrument. Anal. Chem. 87, 2360–2366. https://doi.org/10.1021/ac5042268 (2015).
Article CAS PubMed Google Scholar
Meijer, M. S. et al. Absolute upconversion quantum yields of blue- emitting LiYF4: Yb3+, Tm3+upconverting nanoparticles. Phys. Chem. Chem. Phys. 20, 22556–22562. https://doi.org/10.1039/c8cp03935f (2018).
Article CAS PubMed Google Scholar
Gaigalas, A. K. & Wang, L. L. Measurement of the fluorescence quantum yield using a spectrometer with an integrating sphere detector. J. Res. Nat. Inst. Stand. Technol. 113, 17–28. https://doi.org/10.6028/jres.113.004 (2008).
Article CAS Google Scholar
Leyre, S. et al. Absolute determination of photoluminescence quantum efficiency using an integrating sphere setup. Rev. Sci. Instrum. 85, 9. https://doi.org/10.1063/1.4903852 (2014).
Article CAS Google Scholar
Herz, E. et al. Relative quantum yield measurements of coumarin encapsulated in core-shell silica nanoparticles. J. Fluoresc. 20, 67–72 (2010).
Article CAS PubMed Google Scholar
Martini, M. et al. How to measure quantum yields in scattering media: Application to the quantum yield measurement of fluorescein molecules encapsulated in sub-100 nm silica particles. J. Appl. Phys. 106, 094304. https://doi.org/10.1063/1.3248302 (2009).
Article ADS CAS Google Scholar
Russin, T. J., Altinoglu, E. I., Adair, J. H. & Eklund, P. C. Measuring the fluorescent quantum efficiency of indocyanine green encapsulated in nanocomposite particulates. J. Phys.-Condens. Matter 22, 9. https://doi.org/10.1088/0953-8984/22/33/334217 (2010).
Article CAS Google Scholar
Behnke, T. et al. Encapsulation of hydrophobic dyes in polystyrene micro- and nanoparticles via swelling procedures. J. Fluoresc. 21, 937–944. https://doi.org/10.1007/s10895-010-0632-2 (2011).
Article CAS PubMed Google Scholar
Behnke, T., Würth, C., Laux, E.-M., Hoffmann, K. & Resch-Genger, U. Simple strategies towards bright polymer particles via one-step staining procedures. Dyes Pigm. 94, 247–257 (2012).
Article CAS Google Scholar
Felbeck, T. et al. Nile-red-nanoclay hybrids: Red emissive optical probes for use in aqueous dispersion. Langmuir 29, 11489–11497. https://doi.org/10.1021/la402165q (2013).
Article CAS PubMed Google Scholar
Behnke, T. et al. Target-specific nanoparticles containing a broad band emissive NIR dye for the sensitive detection and characterization of tumor development. Biomaterials 34, 160–170. https://doi.org/10.1016/j.biomaterials.2012.09.028 (2013).
Article ADS CAS PubMed Google Scholar
Hoffmann, K., Behnke, T., Grabolle, M. & Resch-Genger, U. Nanoparticle-encapsulated vis- and NIR-emissive fluorophores with different fluorescence decay kinetics for lifetime multiplexing. Anal. Bioanal. Chem. 406, 3315–3322. https://doi.org/10.1007/s00216-013-7597-3 (2014).
Article CAS PubMed Google Scholar
Würth, C., Pauli, J., Lochmann, C., Spieles, M. & Resch-Genger, U. Integrating sphere setup for the traceable measurement of absolute photoluminescence quantum yields in the near infrared. Anal. Chem. 84, 1345–1352. https://doi.org/10.1021/ac2021954 (2012).
Article CAS PubMed Google Scholar
Hollandt, J. et al. Traceability in fluorometry—part I: Physical standards. J. Fluoresc. 15, 301–313 (2005).
Article CAS PubMed Google Scholar
Laux, E.-M., Behnke, T., Hoffmann, K. & Resch-Genger, U. Keeping particles brilliant—simple methods for the determination of the dye content of fluorophore-loaded polymeric particles. Anal. Methods 4, 1759–1768 (2012).
Article CAS Google Scholar
Goebel, D. G. Generalized integrating-sphere theory. Appl. Opt. 6, 125–128. https://doi.org/10.1364/ao.6.000125 (1967).
Article ADS CAS PubMed Google Scholar
Würth, C., Grabolle, M., Pauli, J., Spieles, M. & Resch-Genger, U. Comparison of methods and achievable uncertainties for the relative and absolute measurement of photoluminescence quantum yields. Anal. Chem. 83, 3431–3439 (2011).
Article PubMed Google Scholar
Würth, C., Grabolle, M., Pauli, J., Spieles, M. & Resch-Genger, U. Relative and absolute determination of fluorescence quantum yields of transparent samples. Nat. Protoc. 8, 1535–1550. https://doi.org/10.1038/nprot.2013.087 (2013).
Article CAS PubMed Google Scholar
Prahl, S. A., Vangemert, M. J. C. & Welch, A. J. Determining the optical properties of turbid Media by using the adding doubling method. Appl. Opt. 32, 559–568 (1993).
Article ADS CAS PubMed Google Scholar
Jonsson, J. C., Smith, G. B. & Niklasson, G. A. Experimental and Monte Carlo analysis of isotropic multiple Mie scattering. Opt. Commun. 240, 9–17. https://doi.org/10.1016/j.optcom.2004.06.017 (2004).
Article ADS CAS Google Scholar
Palmer, G. M. & Ramanujam, N. Monte Carlo-based inverse model for calculating tissue optical properties. Part I: Theory and validation on synthetic phantoms. Appl. Opt. 45, 1062–1071. https://doi.org/10.1364/AO.45.001062 (2006).
Article ADS PubMed Google Scholar
Galbán, J., Delgado-Camón, A., Sanz, V., Sanz-Vicente, I. & de Marcos, S. A theoretical approach for designing fluorescent reagentless biosensors: The optical model. Anal. Chim. Acta 615, 148–157. https://doi.org/10.1016/j.aca.2008.03.063 (2008).
Article CAS PubMed Google Scholar
Giraev, K. M., Ashurbekov, N. A. & Kobzev, O. V. Optical characterization of biological tissues: Determining absorption and scattering coefficients. Tech. Phys. Lett. 29, 901–903. https://doi.org/10.1134/1.1631358 (2003).
Article ADS CAS Google Scholar
Binzoni, T., Leung, T. S., Gandjbakhche, A. H., Ruefenacht, D. & Delpy, D. T. The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics. Phys. Med. Biol. 51, N313–N322. https://doi.org/10.1088/0031-9155/51/17/n04 (2006).
Article ADS CAS PubMed Google Scholar
Yaroslavsky, A. N., Yaroslavsky, I. V., Goldbach, T. & Schwarzmaier, H. J. Influence of the scattering phase function approximation on the optical properties of blood determined from the integrating sphere measurements. J. Biomed. Opt. 4, 47–53. https://doi.org/10.1117/1.429920 (1999).
Article ADS CAS PubMed Google Scholar
Filipe, V., Hawe, A. & Jiskoot, W. Critical evaluation of nanoparticle tracking analysis (NTA) by NanoSight for the measurement of nanoparticles and protein aggregates. Pharm. Res. 27, 796–810. https://doi.org/10.1007/s11095-010-0073-2 (2010).
Article CAS PubMed PubMed Central Google Scholar
Shang, J. & Gao, X. H. Nanoparticle counting: Towards accurate determination of the molar concentration. Chem. Soc. Rev. 43, 7267–7278. https://doi.org/10.1039/c4cs00128a (2014).
Article CAS PubMed PubMed Central Google Scholar
Mätzler, C. matlab functions for mie scattering and absorption, version 2. Institute of Applied Physics, University of Bern. https://doi.org/10.7892/boris.146550 (2002).
Harvey, A. H., Gallagher, J. S. & Sengers, J. Revised formulation for the refractive index of water and steam as a function of wavelength, temperature and density. J. Phys. Chem. Ref. Data 27, 761–774 (1998).
Article ADS CAS Google Scholar
Ma, X. Y. et al. Determination of complex refractive index of polystyrene microspheres from 370 to 1610 nm. Phys. Med. Biol. 48, 4165–4172. https://doi.org/10.1088/0031-9155/48/24/013 (2003).
Article PubMed Google Scholar
Gienger, J., Bar, M. & Neukammer, J. Extinction spectra of suspensions of microspheres: Determination of the spectral refractive index and particle size distribution with nanometer accuracy. Appl. Opt. 57, 344–355. https://doi.org/10.1364/ao.57.000344 (2018).
Article ADS CAS PubMed Google Scholar
Gienger, J., Gross, H., Neukammer, J. & Bar, M. Determining the refractive index of human hemoglobin solutions by Kramers-Kronig relations with an improved absorption model. Appl. Opt. 55, 8951–8961. https://doi.org/10.1364/ao.55.008951 (2016).
Article ADS PubMed Google Scholar
Rodriguez, H. B. & Roman, E. S. In Fluorescence Methods and Applications: Spectroscopy, Imaging, and Probes Vol. 1130 Annals of the New York Academy of Sciences (ed Wolfbeis, O. S.) 247–252 (2008).
Rodriguez, H. B. & Roman, E. S. Effect of concentration on the photophysics of dyes in light-scattering materials. Photochem. Photobiol. 89, 1273–1282. https://doi.org/10.1111/php.12107 (2013).
Article CAS PubMed Google Scholar
Rodriguez, H. B., Iriel, A. & San-Roman, E. Energy transfer among dyes on particulate solids. Photochem. Photobiol. 82, 200–207 (2006).
Article CAS PubMed Google Scholar
Rodriguez, H. B. & Roman, E. S. Energy transfer from chemically attached rhodamine 101 to adsorbed methylene blue on microcrystalline cellulose particles. Photochem. Photobiol. 83, 547–555. https://doi.org/10.1562/2006-08-01-ra-993 (2007).
Article CAS PubMed Google Scholar
Hennig, A., Hatami, S., Spieles, M. & Resch-Genger, U. Excitation energy migration and trapping on the surface of fluorescent poly(acrylic acid)-grafted polymer particles. Photochem. Photobiol. Sci. 12, 729–737. https://doi.org/10.1039/c2pp25364j (2013).
Article CAS PubMed Google Scholar
Zhou, H. et al. Cell-free measurements of brightness of fluorescently labeled antibodies. Sci. Rep. 7, 41819. https://doi.org/10.1038/srep41819 (2017).
Article ADS CAS PubMed PubMed Central Google Scholar
Download references
This project (METVES II; grant number 18HLT01) has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme. We gratefully acknowledge discussions of project results with Dr. D. Geißler (BAM), Drs. E. van der Pol and Rienk Nieuwland (University of Amsterdam, AMC), and Dr. Martine Kuiper (VSL). In addition, UR gratefully acknowledges funding from the German research council (DFG; grant SIREN).
Open Access funding enabled and organized by Projekt DEAL.
Division Biophotonics, Bundesanstalt für Materialforschung und –prüfung (BAM), Richard-Willstaetter Str. 11, 12489, Berlin, Germany
Christian Würth, Thomas Behnke & Ute Resch-Genger
Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2–12, 10587, Berlin, Germany
Jonas Gienger
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
T.B. prepared the dye-stained particles and characterized them analytically. J.G. did the simulation and data analysis with Mie theory and Kramers Kronig relations. C.W. designed the integrating sphere setup, built it, performed the spectroscopic measurements and the remaining data analysis. C.W. and U.R. led the discussions and wrote the manuscript. All authors reviewed and approved the manuscript.
Correspondence to Christian Würth or Ute Resch-Genger.
The authors declare no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
Würth, C., Behnke, T., Gienger, J. et al. Efficiency scale for scattering luminescent particles linked to fundamental and measurable spectroscopic properties. Sci Rep 13, 6254 (2023). https://doi.org/10.1038/s41598-023-32933-6
Download citation
Received: 25 January 2023
Accepted: 04 April 2023
Published: 17 April 2023
DOI: https://doi.org/10.1038/s41598-023-32933-6